Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(19)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37834266

RESUMO

A novel derivative of ciprofloxacin (Cpx) was synthesized and characterized using various analytical techniques, including FT-IR spectroscopy, UV-Vis spectroscopy, TEM and SEM analysis, 1H NMR, 13C NMR, and HPLC analysis. The newly prepared Cpx derivative (Cpx-Drv) exhibited significantly enhanced antibacterial properties compared to Cpx itself. In particular, Cpx-Drv demonstrated a 51% increase in antibacterial activity against S. aureus and a 30% improvement against B. subtilis. It displayed potent inhibitory effects on topoisomerases II (DNA gyrase and topoisomerase IV) as potential molecular targets, with IC50 values of 6.754 and 1.913 µg/mL, respectively, in contrast to Cpx, which had IC50 values of 2.125 and 0.821 µg/mL, respectively. Docking studies further supported these findings, showing that Cpx-Drv exhibited stronger binding interactions with the gyrase enzyme (PDB ID: 2XCT) compared to the parent Cpx, with binding affinities of -10.3349 and -7.7506 kcal/mole, respectively.


Assuntos
Ciprofloxacina , Staphylococcus aureus , Ciprofloxacina/farmacologia , Ciprofloxacina/química , Cromatografia Líquida de Alta Pressão , Espectroscopia de Infravermelho com Transformada de Fourier , Testes de Sensibilidade Microbiana , Antibacterianos/química , DNA Girase , Simulação de Acoplamento Molecular , Inibidores da Topoisomerase II/farmacologia , Inibidores da Topoisomerase II/química
2.
BMC Chem ; 17(1): 72, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37438790

RESUMO

Cefoperazone (Cfz) is a member of the third generation of parenteral cephalosporin antibiotics. It is used on a wide scale in prescribed antibiotic drugs as anti-infection, especially for Gram-negative and also against Gram-positive microorganisms. The current study aimed to find a rapid RP-HPLC method of Cfz analysis with high linearity, repeatability, sensitivity, selectivity, and inexpensive. In our developed method, there is no need to use special chemical reagents, a high percentage of organic solvent, a high flow rate, further guard column. The chromatographic system comprises an ODS column (150 mm × 4.6 mm × 5 µm). The mobile phase was prepared by mixing KH2PO4 solution: acetonitrile (80:20) with a flow rate of 1.0 mL/min at detection wavelength 230 nm, at room temperature using injection volume 20 µL. The method manifested a satisfied linearity regression R2 (0.9993) with a good repeatability range (0.34-0.92%) with LOD and LOQ; 4.04 µg/mL and 12.24 µg/mL respectively. The method proved its efficiency via system suitability achievement in the robustness and ruggedness conduction according to the validation guidelines. The shorter analysis time makes the method very valuable in quality control to quantify the commercial Cfz in pharmaceutical preparations. This improved HPLC method has been successfully applied for Cfz analysis for Peracef and Peractam vials in our routine finished and stability studies testing laboratories. Additionally, the detection limit of Cfz has been tested in our quality control lab to detect the smallest amount of traces that may be present after the cleaning process of the production machines for cephalosporins preparations. In a precedent for the first time, we were able to use the current analysis method to determine the minimum inhibitory concentration (MIC) and minimum bacteriostatic concentration (MBC). The conventional broth micro-dilution tube method was used to determine MIC at 250 µg/mL and MBC at 125 µg/mL of Cfz against the standard strain of Burkholderia cepacia (B. cepacia) ATCC 25416 as Gram-negative bacteria in vitro.

3.
Clin Kidney J ; 8(4): 415-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26251708

RESUMO

Four bodybuilders who injected anabolic steroids and ingested commercial protein (78-104 g/day) and creatine (15 g/day) products presented with serum creatinine levels between 229.84 and 335.92 µmol/L (2.6-3.8 mg/dL). Renal biopsies revealed acute tubular necrosis. Four weeks after discontinuing injections and supplements, serum creatinine was in the normal range and estimated glomerular filtration rate > 1.00 mL/s (60 mL/min), including two patients with biopsies showing >30% interstitial fibrosis and tubular atrophy. The findings highlight a risk for acute and potentially chronic kidney injury among young men abusing anabolic steroids and using excessive amounts of nutritional supplements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...